Weather
The Weather feature supports traditional meteorological sensors that provide simple pulse or analog signals.
A YuDash data logger can directly measure:
Wind Speed from a pulse-generating anemometer
Wind Direction from a potentiometer-based wind vane
Rainfall from a tipping-bucket rain gauge
These measurements are handled differently inside the data logger.
Wind speed is calculated over a configurable measurement window. Pulses are counted during the selected sample duration and converted into a wind-speed value using the configured calibration factor.
Rainfall, on the other hand, is accumulated continuously in the background. Each tipping-bucket pulse represents a known amount of rainfall and is added to the relevant rainfall counters.
Wind direction is typically acquired as an analog voltage from the wind-vane potentiometer and converted to 0–359° using analog measurement and data scaling.
Compact weather stations with internal electronics may provide wind and rainfall parameters directly over Modbus, SDI-12 or serial/ASCII interfaces. Those sensors are handled through the corresponding digital sensor interface rather than through the direct Weather measurements described here.
Wind Speed and Direction
Wind speed is measured from pulses generated as the cups rotate. The YuDash data logger counts these pulses over a configured sample window and converts the measured pulse rate into wind speed using the configured sensor factor. The resulting value can then be represented in the required engineering units, such as m/s, km/h, mph or knots, depending on the application.
Wind direction is usually measured using a potentiometer connected to the wind vane. The changing potentiometer position produces an analog voltage, which is measured by the YuDash data logger and scaled into the required angular representation. A typical application may use degrees (0–359°), while other angular units such as radians may also be used where required.
Configure Wind Speed & Direction
The following example explains the Weather configuration using the Davis 6410 anemometer, which provides both wind-speed pulse output and potentiometer-based wind direction.
The same configuration workflow can be used with other traditional anemometers. Sensor-specific wiring, pulse factors, debounce values and direction scaling must be set according to the connected sensor. Detailed sensor wiring is covered separately under Sensor Integrations.
If the installation uses a wind-speed-only sensor, the Wind Direction configuration can be skipped.
For this example:
Wind Speed is measured through the Weather pulse input.
Wind Direction is measured through an analog input and converted to the required angular units using Data Scaling.
The following steps show the complete configuration.
Our primary worked example is the Davis anemometer, which is widely used in weather and hydrometeorological installations.
Connect the Davis 6410 to FELYX
For this example:
DI1 is used for wind-speed pulse counting.
C5 is used for the 0–5 V wind-direction signal.
V5B provides the potentiometer excitation supply.
GND is common to the sensor.
Wind speed and wind direction are independent measurements even though both are carried through the same Davis RJ11 cable.

Configure Wind Speed
The Davis 6410 wind-speed output is connected to DI2. FELYX counts the incoming pulses and converts them into a wind-speed value inside the Weather block.
Open Weather → Wind Speed and enable Wind Speed.

For this example:
Cloud Variable Name
wind_speed
Variable generated by FELYX
Speed Factor
0.1667
Calibration factor used to convert the measured pulse count/frequency into wind speed
Debounce
5 ms
Rejects very closely spaced transitions or electrical noise
Sample Window
10000 ms
Measurement window over which the wind-speed pulses are evaluated
The Speed Factor depends on the pulse-to-speed relationship of the connected anemometer. The value shown above is the factor used for this Davis 6410 integration.
Configure Wind Direction Input
Wind direction from the Davis 6410 is obtained from the potentiometer wiper on the green conductor. With the potentiometer powered from the FELYX 5 V supply, the direction signal is measured as a 0–5 V analog input.
Open: Sensor Settings → Analog
Enable Channel 5 / C5 and configure it as:

Setting
Value
Topology
C5: 0–5000 mV
Input Min
0
Input Max
5000
Output Min
0
Output Max
5000
Multiplier
1
Variable
w_direction
At this stage, FELYX is measuring the raw wind-direction signal in millivolts.
The Davis 6410 uses a wind vane and potentiometer for direction sensing; the green wire is the potentiometer wiper and the yellow wire is its supply
Step 6 — Verify Wind Data
After saving the configuration, open the YuDash Local Dashboard and verify the generated wind variables

In this test, approximately 2.3 V was applied to the wind-direction input C5. The dashboard shows:
analog_5= 2307.07 mV — raw analog inputw_direction= 165.648° — scaled wind-direction valuewind_speed— wind-speed value generated from the pulse input
With the configured scaling of 0–5000 mV → 0–359°.
The dashboard therefore confirms that the analog wind-direction signal is being acquired and converted correctly.
During commissioning, rotate the wind vane and anemometer to confirm that both
w_directionandwind_speedrespond correctly across their operating range.
Rain Gauge
A tipping-bucket rain gauge converts rainfall into a sequence of electrical pulses.
Rainwater is collected through the funnel and directed into a small two-sided tipping bucket. As one side fills to a calibrated volume, the bucket tips and empties. A magnet attached to the tipping mechanism passes a reed switch, creating one electrical pulse for each tip.
Each pulse therefore represents a known amount of rainfall, defined by the sensor calibration or mm per tip value.
How FELYX Measures Rainfall
The rain-gauge output is connected to the YuDash data logger as a simple pulse input.
For the example shown here:
one reed-switch wire is connected to DI1
the second wire is connected to GND
every valid bucket tip produces one pulse
the data logger continuously counts these pulses in the background
the pulse count is converted into rainfall using the configured mm per tip value

Unlike wind speed, rainfall is not calculated only during a short sample window. The rain counter remains active continuously so that individual bucket tips are not missed.
A debounce setting is used to prevent contact bounce or electrical noise from causing a single physical tip to be counted more than once.
Rainfall accuracy depends on correct sensor settings. The configured
mm per tip, debounce and pulse-input wiring must match the rain-gauge manufacturer's specification.
Configure Rain Gauge
1) The wiring shown below is a representative example of connecting the Davis 6464 tipping-bucket rain gauge to a YuDash data logger using the sensor's RJ11 cable.
In standard terminal-input configurations, the rain pulse and ground conductors are connected to the appropriate DI and GND terminals. YuDash also offers product variants with direct RJ11 sensor connectors for simplified Davis installations.

2) Open Sensor Settings → Weather → Rain Gauge and enable Rain Gauge.

3) Rain Gauge Settings
Setting
Example
Description
Gauge Mode
0 — ISR (no deep sleep)
Standard rain-pulse counting mode. Keep this at 0 for normal installations. Other modes are intended for experimental/special use.
mm Per Tip
0.2
Rainfall represented by one valid bucket tip. This value must match the rain-gauge calibration.
Debounce
50 ms
Rejects additional contact transitions occurring immediately after a valid tip.
Start of Day
0
Defines when the daily rainfall counter rolls over, in minutes after local 00:00.
Rain Data Directory
/rain_dir
Internal SD-card directory used by the rain-processing system.
Do not modify or delete files inside
/rain_dir. These files are maintained internally by the YuDash data logger for rainfall calculations and counter continuity.
4) Rainfall Variables
The Weather feature maintains four rainfall variables. These values are refreshed on approximately a one-minute basis.
rain_today
Total rainfall accumulated during the current configured rainfall day
rain_yesterday
Total rainfall accumulated during the previous rainfall day
rain_curr_hr
Rainfall accumulated during the current clock hour
rain_prev_hr
Total rainfall accumulated during the immediately preceding clock hour
The variable names can be changed to suit the destination application.
Current Hour and Previous Hour
rain_curr_hr accumulates rainfall during the current local clock hour.
At the hour rollover, the completed value is transferred to rain_prev_hr, while rain_curr_hr starts again from zero.
5) Start of Day
Rainfall calculations use the device local time. By default, the rainfall day changes at 00:00 local time.
The Start of Day setting allows this rollover time to be shifted to match the reporting convention required by the applicable meteorological department or project specification. The value is entered as the number of minutes after midnight.
For example:
This setting affects rainfall calculations only. It does not change the device clock or the timestamp used by other measurements.
How Rainfall Variables Update
The example below illustrates how rain_today, rain_yesterday, rain_curr_hr, and rain_prev_hr change over time during rainfall.
It also shows how the configured Start of Day and hourly rollover affect the accumulated values.

Last updated