YuDash
  • Welcome
  • YuDash IoT Products
    • LYNX User Manual
      • Terminals and Wiring
      • LYNX Configuration
      • Network Settings
      • LYNX Settings
        • Modbus RS485
        • Analog Inputs
        • Data Scaling
        • Advance Feature Settings
        • Cloud and Payload Settings
        • Ethernet Settings
        • Modbus TCP/IP
        • HTML Parser Settings
        • Digital Sensors Settings
    • ZENYX User Manual
      • Terminals and Wiring
      • ZENYX Configuration
      • Network Settings
      • ZENYX Settings
        • Modbus RS485
        • Analog Inputs
        • Data Scaling
        • Advance Feature Settings
        • Cloud and Payload Settings
        • Ethernet Settings
        • Modbus TCP/IP
    • ONYX
    • Setu
    • QUBIX
  • Device Configuration
    • Device Configuration
    • Device Features
      • Network
      • Modbus/RS485
        • Modbus Poll Tutorial
        • String read in RS485/RS232
      • Modbus TCP/IP
      • Modbus Server
        • Analog to Modbus/RS485 Server (Slave)
        • Analog to Modbus/TCP-IP Server
      • Ethernet
      • Data Logging
      • YuDash Axon
        • YuParse
  • Firmware
    • Firmware release notes
    • Firmware upgrade
  • YuDash JSON API
    • Modbus Settings
    • Analog Settings
    • Data Scale Settings
  • DEVICE TO CLOUD API
    • YuDash IIoT Stack
    • Cloud Protocols
      • MQTT
      • HTTP
      • FTP
      • SSL/TLS
        • MQTT with Self Signed TLS
    • Payload Formats
      • JSON Payloads
      • YuTGT: YuDash Text Generator
    • Network Connectivity
    • Industrial Protocols
      • Modbus
  • YuDash IoT Platform
    • YuReCon
  • Integration Guides
    • IoT Platform Integration
      • Ubidots
      • TagoIO
      • Losant
      • Datacake
      • Eagle.io
      • Boodskap
      • Statstream
      • Qubitro
      • Thingsboard
    • Industrial Instruments
      • Energy
        • SE EM6400NG+
        • Selec MFM376
        • L&T WL 4040
        • Entes MPR-46S
        • Selec EM4M
        • Secure Elite 100
        • Siemens Smart 7KT
        • Selec EM2M
      • Process Control
        • Selec FLEX2MV3 6AII
        • Selec MiBRX 2M PLC
        • Temp+Humidity XY-MD02
        • PPI AIMS 4/8X
    • Environment/Emission
      • Air & Water
      • Weather
    • Industrial PLCs
  • Use Cases
    • Environment
      • Ground Water Compliance
      • Continuous Emission Monitoring System (CEMS)
    • Smart Building
      • IoT based Building Monitoring Solution
      • Tenant Energy Sub-metering and Billing System
    • Asset Management
      • Centralized Monitoring System for Gas Plant OEM
Powered by GitBook
On this page
  1. YuDash JSON API

Analog Settings

1) Analog Input Settings

anaToDigSettings

Analog Input (4-20mA) input Settings

   "anaToDigSettings": {
    "anaToDigCnt": 8,
    "anaToDigArray": [
      {
        "anaToDigType": 1,
        "minOutVal": 0,
        "maxOutVal": 20,
        "minmA": 0,
        "maxmA": 20,
        "dcRes": 68,
        "varName": "VOC",
        "varName2": "VOC_MA",
        "varFactor": 1
      },
      // .. upto 4 or 8 channels 
 
      //...
      {
        "anaToDigType": 1,
        "minOutVal": 0,
        "maxOutVal": 20,
        "minmA": 0,
        "maxmA": 20,
        "dcRes": 68,
        "varName": "A8",
        "varFactor": 1,
        "varName2": ""
      }
    ]
  },

JSON key
Description
Remarks

anaToDigCnt

anaToDigType

minmA, maxmA

minOutVal, maxOutVal

varName

varName2

dcRes

varFactor

PreviousModbus SettingsNextData Scale Settings

Last updated 2 months ago